Pilz PSENvip RL D P Manuale Utente Pagina 81

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 139
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 80
Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: [email protected]
6-7
6.2 Connections
6 Wiring
6.2.5 Connection diagram
Connection diagram6-Verdrahtung_Anschluss_Schema_dyn_mute
Fig. 6-6: Connection diagram
1
PSENvip
Receiver
X1
PSENvip
Transmitter
2
3
4
5
6
7
8
Protected field mode 1 / Tool class PLC -> PSENvip Bit 1
Protected field mode 2 / Tool class PLC -> PSENvip Bit 2 *)
OSSD 1
Mute 1 / Tool class PSENvip -> PLC Bit 1 *)
1
2
3
4
5
6
7
8
1
2
3
4
24 V DC
0 V
Power Off (Setup) / PLC Ready *)
Acknowledgement
System-Init
OSSD 2
TRM_ON
TRM_SYNC
TRM_ON
TRM_SYNC
X2
X3
Mute 2 / Tool class PSENvip -> PLC Bit 2 *)
Activate *)
Acknowledge PSENvip -> PLC *)
*) Used in communication between
PSENvip and safety system
Vedere la pagina 80
1 2 ... 76 77 78 79 80 81 82 83 84 85 86 ... 138 139

Commenti su questo manuale

Nessun commento