4.7 System cycle
4 Function Description
Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: [email protected]
4-36
2
3
4
State Downward movement
Rapid traverse
Foot switch 1
System-Init 0
OSSD 1
Creep speed mode SG 0
Protected field Free
State Downward movement
Creep speed mode signal
Foot switch 1
System-Init 0
OSSD 1
Creep speed mode SG 1
Protected field Free
State Bottom dead centre
Foot switch 1
System-Init 0
OSSD 0
Creep speed mode SG 1
Protected field Interrupted
v = 0
v > 10 mm/s
v £ 10 mm/s
v = 0
v = 0
v > 10 mm/s
v £ 10 mm/s
v = 0
v = 0
v > 10 mm/s
v £ 10 mm/s
v = 0