Pilz PSENvip RL D P Manuale Utente Pagina 65

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
Vedere la pagina 64
Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: [email protected]
4-37
4.7 System cycle
4 Function Description
5
6
4.7.3 System cycle for back gauge press stroke
System cycle for back gauge press stroke4-Funktion_Systemablauf_Pressenhub_mit_Anschlag
Inputs on the PSENvip receiver:
Protected field mode 1 = 1
Protected field mode 2 = 0
Acknowledgement of reduced protected field = Press pushbutton
and then release
The system cycle is the same as for box bending. Please note that with
back gauge protected field mode, the rear segments of the protected
field are blanked.
State Upward movement
Rapid traverse
Foot switch 1
System-Init 1
OSSD 1 or 0
Creep speed mode SG 0
Protected field Free or interrupted
State Press is at top dead centre
Foot switch 0
System-Init 1
OSSD 1
Creep speed mode SG 0
Protected field Free
v = 0
v > 10 mm/s
v £ 10 mm/s
v = 0
v = 0
v > 10 mm/s
v £ 10 mm/s
v = 0