7.2 Initial commissioning
7 Commissioning
Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: [email protected]
7-8
Examples of the correct adjustment of various tool types:
Tool class 1: Pointed tools
For these tools we recommend alignment to
the left-hand bending line. The distance from
the bending line to the front segments of the
protected field is >15 mm.
Tool class 2: Semi-circular tools
For these tools we recommend alignment to
the left-hand bending line. The distance from
the front bending line of the tool to the front
segments of the protected field is <15 mm.
The rear bending line of the tool is detected
by the protected field. The position of the
front bending line must be considered in the
hazard analysis.
Tool class 2: Stamp
For these tools we recommend alignment to
the central bending line. The distance from
the front bending line of the tool to the front
segments of the protected field is <15 mm.
The rear bending line of the tool is detected
by the protected field. The position of the
front bending lines must be considered in the
hazard analysis.
Tool class 3: Stamp
The front and rear bending lines of the tool
are outside the protected field. The position
of the bending lines must be considered in
the hazard analysis.
> 15 mm
< 15 mm
< 15 mm